ezSPAN® All-Dielectric Self-Supporting ADSS Cable
Prysmian's ezSPAN® All-Dielectric Self-Supporting ADSS cables provide reliable self-supporting performance over distances of up to 1,200 feet (365 meters). Each ezSPAN® ADSS cable is custom-engineered for its specific application, taking into account the full weather load to ensure safe and dependable performance throughout its lifetime. The flexible buffer tubes simplify mid-entry, preparation, and routing within splice closures. These cables combine flexible buffer tubes with gel water-blocking technology, making ezSPAN® robust and user-friendly ADSS cables to place in the network.
Ordering Guide: Fiber Outdoor Ordering Guide
Additional Resources: Color Code Guide for Fiber Optic Specifications, Fiber Code Addendum, International Standards and Fiber Products Table
Part Numbers
Prysmian’s ADSS part numbers include the Maximum Rated Cable Load (MRCL), which creates a wide array of potential numbers that are engineered-to-order. There are too many variations to list here. Please consult your Prysmian sales representative for further details on specifying your ezSpan ADSS cable. You may also fill out our ADSS questionnaire at the end of the ezSpan Product Datasheet to include the necessary information for quoting.
US Part Numbers
F-ADSS0465-06-HB-XXX, F-ADSS0415-12-HB-XXX, F-ADSS0495-12-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1075-12-HB-XXX, F-ADES1205-12-HB-XXX, F-ADES1345-12-HB-XXX, F-ADES1475-12-HB-XXX, F-ADES1615-12-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1115-12-HB-XXX, F-ADES1255-12-HB-XXX, F-ADES1435-12-HB-XXX, F-ADES1615-12-HB-XXX, F-ADES1795-12-HB-XXX, F-ADES1925-12-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1075-12-HB-XXX, F-ADES1295-12-HB-XXX, F-ADES1525-12-HB-XXX, F-ADES1705-12-HB-XXX, F-ADES1925-12-HB-XXX, F-ADES2125-12-HB-XXX, F-ADSS0465-06-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1115-12-HB-XXX, F-ADES1295-12-HB-XXX, F-ADES1525-12-HB-XXX, F-ADES1705-12-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1255-12-HB-XXX, F-ADES1475-12-HB-XXX, F-ADES1705-12-HB-XXX, F-ADES1885-12-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1295-12-HB-XXX, F-ADES1565-12-HB-XXX, F-ADES1835-12-HB-XXX, F-ADES2105-12-HB-XXX, F-ADES2375-12-HB-XXX, F-ADSS0465-06-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1075-12-HB-XXX, F-ADES1255-12-HB-XXX, F-ADES1385-12-HB-XXX, F-ADES1525-12-HB-XXX, F-ADES1705-12-HB-XXX, F-ADES1885-12-HB-XXX, F-ADES2195-12-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1165-12-HB-XXX, F-ADES1345-12-HB-XXX, F-ADES1525-12-HB-XXX, F-ADES1705-12-HB-XXX, F-ADES1885-12-HB-XXX, F-ADES2015-12-HB-XXX, F-ADES2375-12-HB-XXX, F-ADES1025-12-HB-XXX, F-ADES1205-12-HB-XXX, F-ADES1385-12-HB-XXX, F-ADES1615-12-HB-XXX, F-ADES1795-12-HB-XXX, F-ADES1975-12-HB-XXX, F-ADES2195-12-HB-XXX, F-ADES2375-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1071-12-HB-XXX, F-ADED1211-12-HB-XXX, F-ADED1391-12-HB-XXX, F-ADED1521-12-HB-XXX, F-ADED1701-12-HB-XXX, F-ADED1881-12-HB-XXX, F-ADED2021-12-HB-XXX, F-ADED2201-12-HB-XXX, F-ADED2381-12-HB-XXX, F-ADED2561-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1071-12-HB-XXX, F-ADED1251-12-HB-XXX, F-ADED1431-12-HB-XXX, F-ADED1661-12-HB-XXX, F-ADED1841-12-HB-XXX, F-ADED2021-12-HB-XXX, F-ADED2201-12-HB-XXX, F-ADED2421-12-HB-XXX, F-ADED2621-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1211-12-HB-XXX, F-ADED1481-12-HB-XXX, F-ADED1701-12-HB-XXX, F-ADED1971-12-HB-XXX, F-ADED2201-12-HB-XXX, F-ADED2471-12-HB-XXX, F-ADED2751-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1211-12-HB-XXX, F-ADED1431-12-HB-XXX, F-ADED1661-12-HB-XXX, F-ADED1881-12-HB-XXX, F-ADED2111-12-HB-XXX, F-ADED2291-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1161-12-HB-XXX, F-ADED1391-12-HB-XXX, F-ADED1611-12-HB-XXX, F-ADED1841-12-HB-XXX, F-ADED2111-12-HB-XXX, F-ADED2331-12-HB-XXX, F-ADED2621-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1161-12-HB-XXX, F-ADED1431-12-HB-XXX, F-ADED1751-12-HB-XXX, F-ADED2021-12-HB-XXX, F-ADED2331-12-HB-XXX, F-ADED2621-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1161-12-HB-XXX, F-ADED1341-12-HB-XXX, F-ADED1481-12-HB-XXX, F-ADED1661-12-HB-XXX, F-ADED1841-12-HB-XXX, F-ADED2021-12-HB-XXX, F-ADED2201-12-HB-XXX, F-ADED2381-12-HB-XXX, F-ADED2511-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1071-12-HB-XXX, F-ADED1251-12-HB-XXX, F-ADED1431-12-HB-XXX, F-ADED1611-12-HB-XXX, F-ADED1841-12-HB-XXX, F-ADED2021-12-HB-XXX, F-ADED2201-12-HB-XXX, F-ADED2381-12-HB-XXX, F-ADED2561-12-HB-XXX, F-ADED1031-12-HB-XXX, F-ADED1071-12-HB-XXX, F-ADED1301-12-HB-XXX, F-ADED1521-12-HB-XXX, F-ADED1751-12-HB-XXX, F-ADED1931-12-HB-XXX, F-ADED2157-12-HB-XXX, F-ADED2381-12-HB-XXX, F-ADED2621-12-HB-XXX
Global Part Numbers
M-ADSS0465-06-HB-XXX, M-ADSS0415-12-HB-XXX, M-ADSS0495-12-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1075-12-HB-XXX, M-ADES1205-12-HB-XXX, M-ADES1345-12-HB-XXX, M-ADES1475-12-HB-XXX, M-ADES1615-12-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1115-12-HB-XXX, M-ADES1255-12-HB-XXX, M-ADES1435-12-HB-XXX, M-ADES1615-12-HB-XXX, M-ADES1795-12-HB-XXX, M-ADES1925-12-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1075-12-HB-XXX, M-ADES1295-12-HB-XXX, M-ADES1525-12-HB-XXX, M-ADES1705-12-HB-XXX, M-ADES1925-12-HB-XXX, M-ADES2125-12-HB-XXX, M-ADSS0465-06-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1115-12-HB-XXX, M-ADES1295-12-HB-XXX, M-ADES1525-12-HB-XXX, M-ADES1705-12-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1255-12-HB-XXX, M-ADES1475-12-HB-XXX, M-ADES1705-12-HB-XXX, M-ADES1885-12-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1295-12-HB-XXX, M-ADES1565-12-HB-XXX, M-ADES1835-12-HB-XXX, M-ADES2105-12-HB-XXX, M-ADES2375-12-HB-XXX, M-ADSS0465-06-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1075-12-HB-XXX, M-ADES1255-12-HB-XXX, M-ADES1385-12-HB-XXX, M-ADES1525-12-HB-XXX, M-ADES1705-12-HB-XXX, M-ADES1885-12-HB-XXX, M-ADES2195-12-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1165-12-HB-XXX, M-ADES1345-12-HB-XXX, M-ADES1525-12-HB-XXX, M-ADES1705-12-HB-XXX, M-ADES1885-12-HB-XXX, M-ADES2015-12-HB-XXX, M-ADES2375-12-HB-XXX, M-ADES1025-12-HB-XXX, M-ADES1205-12-HB-XXX, M-ADES1385-12-HB-XXX, M-ADES1615-12-HB-XXX, M-ADES1795-12-HB-XXX, M-ADES1975-12-HB-XXX, M-ADES2195-12-HB-XXX, M-ADES2375-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1071-12-HB-XXX, M-ADED1211-12-HB-XXX, M-ADED1391-12-HB-XXX, M-ADED1521-12-HB-XXX, M-ADED1701-12-HB-XXX, M-ADED1881-12-HB-XXX, M-ADED2021-12-HB-XXX, M-ADED2201-12-HB-XXX, M-ADED2381-12-HB-XXX, M-ADED2561-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1071-12-HB-XXX, M-ADED1251-12-HB-XXX, M-ADED1431-12-HB-XXX, M-ADED1661-12-HB-XXX, M-ADED1841-12-HB-XXX, M-ADED2021-12-HB-XXX, M-ADED2201-12-HB-XXX, M-ADED2421-12-HB-XXX, M-ADED2621-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1211-12-HB-XXX, M-ADED1481-12-HB-XXX, M-ADED1701-12-HB-XXX, M-ADED1971-12-HB-XXX, M-ADED2201-12-HB-XXX, M-ADED2471-12-HB-XXX, M-ADED2751-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1211-12-HB-XXX, M-ADED1431-12-HB-XXX, M-ADED1661-12-HB-XXX, M-ADED1881-12-HB-XXX, M-ADED2111-12-HB-XXX, M-ADED2291-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1161-12-HB-XXX, M-ADED1391-12-HB-XXX, M-ADED1611-12-HB-XXX, M-ADED1841-12-HB-XXX, M-ADED2111-12-HB-XXX, M-ADED2331-12-HB-XXX, M-ADED2621-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1161-12-HB-XXX, M-ADED1431-12-HB-XXX, M-ADED1751-12-HB-XXX, M-ADED2021-12-HB-XXX, M-ADED2331-12-HB-XXX, M-ADED2621-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1161-12-HB-XXX, M-ADED1341-12-HB-XXX, M-ADED1481-12-HB-XXX, M-ADED1661-12-HB-XXX, M-ADED1841-12-HB-XXX, M-ADED2021-12-HB-XXX, M-ADED2201-12-HB-XXX, M-ADED2381-12-HB-XXX, M-ADED2511-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1071-12-HB-XXX, M-ADED1251-12-HB-XXX, M-ADED1431-12-HB-XXX, M-ADED1611-12-HB-XXX, M-ADED1841-12-HB-XXX, M-ADED2021-12-HB-XXX, M-ADED2201-12-HB-XXX, M-ADED2381-12-HB-XXX, M-ADED2561-12-HB-XXX, M-ADED1031-12-HB-XXX, M-ADED1071-12-HB-XXX, M-ADED1301-12-HB-XXX, M-ADED1521-12-HB-XXX, M-ADED1751-12-HB-XXX, M-ADED1931-12-HB-XXX, M-ADED2157-12-HB-XXX, M-ADED2381-12-HB-XXX, M-ADED2621-12-HB-XXX
Key Features
- All-dielectric design allows for safe, reliable aerial self-supporting installation for communication and power transmission networks, with typical span lengths up to 1,200 feet (365 meters).
- Long Span, Safe Strain, Zero Strain and Track Resistant cables are also available.
- Flexible buffer tubes enable easy mid-span entry and simplify routing, storage, and cable preparation within splice closures, especially for FTTx network distribution needs.
- Up to 12 fibers per buffer tube, available in single or dual jacket constructions, support up to 144 fiber counts and enable easier termination and mid-span fiber access.
- Greater than 12 fibers per tube available in ezPlan ADSS cables greater simplifying deployment with a single size attachment hardware through 144 count.
- Features a gel-filled, water-blocking design that resists moisture ingress, while aramid yarns add strength and durability for demanding installations.
- Aramid yarns, or alternatively fiberglass rovings, as strength members of the cable inherently provide significantly improved resistance to rodent chews from squirrels, rats, mice, groundhogs and others.
- Supports industry standards including IEEE 1222, ANSI/ICEA 640, IEC, RUS, and is OHSAS 18001 and ISO 9001/14001 certified for quality and safety assurance.
- Available with bend-insensitive fiber options (G657.A1 and G657.A2 single-mode) to facilitate installation where tight bends are require.
- Designed for fast and safe field preparation with features such as a ripcord for swift outer jacket removal and swellable binders to speed cable prep.
- Engineered for operation under full weather load to ensure dependable performance over its lifetime, minimizing network outages
Applications
Prysmian ezSPAN® ADSS cables are ideal for self-supporting aerial deployments in diverse environments, providing robust connectivity for utility and telecommunication networks where overhead direct attachment is preferred. These ADSS fiber optic cables are especially valued for installations that require little or no support infrastructure modification and where high reliability and resistance to environmental factors are critical.
- Utility Supervisory Control and Data Acquisition (SCADA) Networks
- Point-to-Point (P2P) Networks
- Municipal Networks and Connected Anchor Institutions (CAI)
- Transit railroad networks for street car, interurban and commuter rail networks utilizing catenary
- Access networks
- FTTH (Fiber To The Home)
- PON (Passive Optical Network)
- Sensing networks for power transmission and distribution lines
- Broadband public and private communication networks
- Fiber Deep and HFC overbuilds with limited permitting and clearance on existing poles
Why ADSS Cables From Prysmian?
Prysmian’s ADSS fiber optic cables combine decades of engineering expertise with advanced material science to deliver superior reliability and ease of installation. Every ezSPAN® ADSS cable is custom-engineered to handle site-specific loading conditions, moisture, temperature changes, and mechanical stress, ensuring peace of mind and maximizing network uptime. Prysmian’s meticulous review of your stated span lengths, NESC loading conditions and installed sag mean that our engineered designs will have the utmost reliability and lifespan in the field. Trusted by utilities and network operators, Prysmian cables meet stringent global standards and are supported by technical resources for seamless deployment.
FAQs
What is the ezSpan® ADSS Cable?
The ezSpan® ADSS Cable is an all-dielectric, self-supporting fiber optic cable designed for aerial deployment in utility and telecom networks.
What does “ADSS” mean?
“ADSS” stands for All-Dielectric Self-Supporting, indicating a cable design that is non-metallic and capable of spanning long distances without needing additional support wires. ADSS cables can be placed in the power space above the neutral, or NESC 40 inch worker safety zone, offering unique advantages over traditional “strand and lash” fiber optic cable. Advantages of ADSS include reduced make-ready, permitting and attachment fees. Because it is self-supporting, ADSS cables must have the proper amount of strength elements (aramid and fiberglass) to maintain tensile strength during installation and operation in challenging environments. In the United States, the NESC classifies certain regional loading conditions—light, medium and heavy. In addition to span length, these loading conditions must be taken into account as well as the sag to properly engineer the cable design.
Where is ADSS cable typically used?
ADSS cable is typically used in aerial installations along utility poles or transmission lines for telecommunications, SCADA, and broadband networks. ADSS is often used in private rail networks where catenary poles are available, and also in municipal networks for connected anchor institutions (CAI).
What makes ezSpan® ADSS different from other fiber optic cables?
Prysmian ezSpan® ADSS cables are offered with a few additional design criteria that may not be found elsewhere.
First, ezSpan can be made with SafeStrain (standard) or ZeroStrain designs. In ADSS cables, there is a tolerance for up to 0.20% of strain on the optical fibers per IEEE-1222. To eliminate strain completely, Prysmian ZeroStrain designs ADSS cables with enough aramid strength yarns to avoid fiber breaks due to static fatigue in normal operation.
Second, Prysmian also offers ezPlan designs of ezSpan ADSS which greatly simplify the bill of material for a typical ADSS project. By adjusting the number of fibers per tube, ezPlan cables can maintain the same cable outside diameter up to and include 144 fibers. That change means the hardware used for all fiber counts is the same, reducing complexity and the need to order more hardware to meet minimum quantities.
Lastly, Prysmian is one of a few manufacturers offering track resistant jackets. Track resistant cables are used in proximity to high voltage lines from typically 115 kV to 275kV and designed to withstand dry-band arcing and corona discharges. These phenomena can degrade standard polyethylene fiber optic cable jackets over time. While this feature is more common with Prysmian’s Long Span ADSS for use on high voltage lattice towers, ezSpan cables can come with track resistant jackets as well.
Where can I find product specifications and ordering information?
Product specifications and ordering information are available in the Product Datasheet and the Fiber Outdoor Ordering Guide.