GenSPEED® 5000 Category 5e Outside Plant Cable
Product description
Part Numbers
| Jacket Color | Reel | Armor | |
| Black | 5136100 | - | |
| Black | 5136101 | Aluminum | |
Resources
- GenSPEED® Category 5E Quick Reference Guide
- GenAssurance Product Warranty
- Datacom Cable Quick Reference Guide
Construction
Conductors: 24 AWG solid bare annealed copper
Insulation: Polyolefin
Color Code
- Pair l: Blue-White/Blue
- Pair 2: Orange-White/Orange
- Pair 3: Green-White/Green
- Pair 4: Brown-White/Brown
Optional Armor
- Aluminum applied helically (the inner jacket is used with this construction)
- Armor diameter 12 mm
Flooding Compound: Waterproof gel
Jacket: UV- and Abrasion-Resistant Polyethylene
Features and Benefits
- Protects against environmental elements that can cause electrical performance failures
- TRU-Mark® print legend contains footage markings from 1000' to 0'
- Prevents moisture migration
- Made in U.S.A.
Applications
- IEEE 802.3: 1000 BASE-T, 100 BASE-TX, 10 BASE-T, PoE, PoE+
- CDDI, Token Ring, ATM
- Broadband and Baseband Analog Video
- Armored: aerial, duct and buried installations
- Non-armored design is recommended for duct installation
Standard Compliances
- ANSI/TIA 568.2-E
- UL 444
- RoHS Compliant Directive 2011/65/EU
- ANSI/TIA 862 (Building Automation)
- ICEA S-90-661
- ISO/IEC 11807 Ed. 2.0 (Class D)
- Telcordia (Bellcore) Specification GR- 427- CORE Water Penetration Requirements