S670T Marine Fiber Optic Cable
The S670T series of Marine Shipboard armored fiber optic cables is designed especially for the harsh environments of commercial marine vessels, offshore oil platforms, drilling rigs, and other similar applications.
S670T low-smoke/zero-halogen, flame-retardant cables offer versatility and ease of installation in a construction suited to marine applications. They are compliant with the latest IEC requirements.
S670T cables meet the requirements of IEC 60793-1 and IEC 60792-2 specifications, are encapsulated in all-dielectric, tight-buffered construction, individually reinforced with aramid yarns, and jacketed (breakout style). The breakout components are cabled around a central member, providing additional tensile strength to the entire construction. The thermoplastic low-smoke/zero-halogen double-jacketing system, applied under and over the marine-grade bronze braided armor, offers excellent resistance to chemicals, fluids, fungi, and abrasion.
Construction
Central Strength Member: Dielectric material (epoxy fiberglass rod).
Fiber: Multimode or single-mode fibers with an easily strippable 900µm tight buffering colored per TIA/EIA 598.
Subunit Strength Member: Aramid yarn
Subunut Jacket: 2.0 mm ChromaTek-L™ Halex low smoke zero halogen polyolefin.
Jacket: ChromaTek-L™ Halex low smoke zero halogen polyolefin. ARMOR: Braided bronze in accordance with IEEE 1580 (2010)
Sheath: ChromaTek-L™ Halex low smoke zero halogen polyolefin.
Features and Ratings
- Low smoke/zero halogen construction meets appropriate IEEE and IEC standards for fire, smoke, and toxicity
- Superior resistance to oil, abrasion, moisture, sunlight, crush and impact
- Gigabit ethernet 802.3Z compliant
- Armored and sheathed construction offers additional mechanical & environmental protection
Approvals
- Meets IEC60794-1-1, 60794-1-2 and 60794-2
- Meets IEEE 45 and IEEE 1580
- Det Norske Veritas (DNV)
- American Bureau of Shipping (ABS)
- Lloyd’s Register of Shipping (LRS)
- Flame retardant per IEC 60332-3 CAT. A/F and IEEE 1202
- Smoke density requirements of IEC 61034-1 and 61034-2
- Acid gas generation requirements of IEC 60754-1 & 60754-2
- Toxicity requirements of NES 713
- Meets the performance requirements of IEEE 802.3z (Gigabit Ethernet)