Anaconda® Type SHD-GC EPR/CPE, Shielded Round with Ground-Check
Part Numbers
16245.310200, 16245.310100, 16245.315100, 16299.625200, 16245.615300, 16245.615400, 16245.616000, 16245.616200, 16245.616500
Product Construction
Conductor: 2 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172
Extruded Strand Shield (ESS): Extruded thermosetting semi-conducting stress control layer over conductor
Insulation: Ethylene Propylene Rubber (EPR) insulation colored for contrast with the black conducting layer
Insulation Shield: A flexible coated copper/textile braid shield is applied over a conducting overlapped tape
Ground-Check Conductor: Annealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene
Grounding Conductors
- Coated copper, rope-lay-stranded per ASTM B172
- Two conductors in contact with the flexible copper braid shield
Jacket: Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE)
Jacket Marking: PRYSMIAN MI ANACONDA(R) [XX] [AWG/KCMIL] 3/C TYPE SHD-GC 15000 VOLTS (-50C) FT1 FT5 SR CSA LR 27161 P-7K-102046-1 MSHA
Options
- Colored jackets are available
- TPU (Thermoplastic Polyurethane) jacket
- Neoprene jacket
Applications
Designed for use as a trailing cable on AC mining equipment:
- Where service conditions are severe and maximum safety is mandatory (such as power shovels and draglines in open-pit mines, quarries, gantry cranes and slag reclaiming)
- For high-voltage distribution in underground mines, where frequent relocation is necessary
Features
- Simultaneous extrusion and vulcanization of both the strand shield and insulation form a virtually perfect electrode, eliminating unequal electrical stresses
- Excellent heat, moisture, steam, oil, corona, chemical and radiation resistance
- Flexible for easy handling
- High dielectric strength
- Electrical stability under stress
- Low dielectric loss
- Resists cutting, impact, abrasion, flame and sunlight
- Excellent thermal stability and physical properties over a broad temperature range
- The two-layer jacket is reinforced to provide maximum protection from mechanical damage, the cause of most portable cable failures
Compliances
- ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications
- Meets flame test requirements and is accepted for listing by MSHA
- Approved by the Pennsylvania Department of Environmental Protection
Packaging
Material cut to length and shipped on non- returnable reels