864-1728F MassLink™ Indoor and Indoor/Outdoor with FlexRibbon® Cable
MassLink™ with FlexRibbon® technology features an ultra-compact cable design suitable for both indoor and outdoor applications. It contains between 864 and 1,728 bend-insensitive fibers. This innovative design employs FlexRibbon technology, which allows the fibers to be tightly rolled and packed into small-diameter tubes that hold either 144 or 288 fibers. While FlexRibbon enables high packing density, the 250μm fiber ribbons still benefit from the advantages of mass fusion splicing.
Resources
- Fiber Indoor Ordering Guide
- Fiber Indoor/Outdoor Ordering Guide
- Color Code Guide for Fiber Optic Specifications
- Fiber Code Addendum
- International Standards and Fiber Products Table
- Quick Reference: Installation of Pulling Grip to 864 MassLink™ RICT Cable
- FlexRibbon Tube Preparation
Part Numbers
US
| Fiber Count Range | Recommended Fiber Count | Part Number | Number of Tubes | Ribbons Per Tube | Fibers per Tube | Buffer Tube OD | Cable OD | Approx. Cable Weight | Max. Reel Length | ||||
| in | mm | in | mm | lb/kft | kg/km | feet | meters | ||||||
| INDOOR/OUTDOOR | |||||||||||||
| 12 Fiber Ribbons - MassLink™ Indoor & Indoor/Outdoor with FlexRibbon™ | OFNR/FT4 | |||||||||||||
864-1728 | 864 | F-RRIOLFK-12-B1-864-E3 | 6 | 12 | 144 | 0.26 | 6.6 | 0.95 | 24.2 | 291 | 423 | 20,870 | 6,361 |
| 1152 | F-RRIOLFK-12-B1-1152-E3 |
6 |
24 |
288 |
0.29 |
7.4 |
1.05 |
26.2 |
355 |
529 |
18,715 |
5,704 | |
| 1728 | F-RRIOLFK-12-B1-1728-E3 | ||||||||||||
| 12 Fiber Ribbons - MassLink™ Indoor & Indoor/Outdoor with FlexRibbon™ | LSZH – OFNG ST1 | |||||||||||||
1152-1728 | 1152 | F-RZIOLFK-12-B1-1152-E3 |
6 |
24 |
288 |
0.29 |
7.4 |
1.05 |
26.7 |
372 |
553 |
16,670 |
5,080 |
| 1728 | F-RZIOLFK-12-B1-1728-E3 | ||||||||||||
| 12 & 16 Fiber Ribbons - MassLink™ Indoor & Indoor/Outdoor with FlexRibbon™ | Riser: OFNR/FT4 ST1 CPR: Cca-s1b,d0,a1 | |||||||||||||
| 12 Fiber Ribbons | 1728 | F-RRZIOLFK-12-B1-1728-E3 | 6 | 24 |
288 |
0.29 |
7.4 |
1.11 |
28.1 |
428 |
637 |
15,420 |
4,700 |
| 16 Fiber Ribbons | 1728 | F-RRZIOLFK-16-B1-1728-E3 | 6 | 18 | |||||||||
| INDOOR ONLY | |||||||||||||
| 12 Fiber Ribbons - MassLink™ Indoor Only with FlexRibbon™ | OFNR/FT4 | |||||||||||||
864-1728 | 864 | F-RRLFK-12-B1-864-E3 | 6 | 12 | 144 | 0.26 | 6.6 | 0.95 | 24.2 | 291 | 431 | 20,870 | 6,361 |
| 1152 | F-RRLFK-12-B1-1152-E3 |
6 |
24 |
288 |
0.29 |
7.4 |
1.05 |
26.6 |
355 |
529 |
18,715 |
5,704 | |
| 1728 | F-RRLFK-12-B1-1728-E3 | ||||||||||||
| 12 Fiber Ribbons - MassLink™ Indoor Only FlexRibbon™ | LSZH – OFNG ST1 | |||||||||||||
1152-1728 | 1152 | F-RZLFK-12-B1-1152-E3 |
6 |
24 |
288 |
0.29 |
7.4 |
1.05 |
26.7 |
372 |
553 |
16,670 |
5,080 |
| 1728 | F-RZLFK-12-B1-1728-E3 | ||||||||||||
| 12 & 16 Fiber Ribbons - MassLink™ Indoor Only FlexRibbon™ | LSZH – OFNR/FT4 ST1 CPR: Cca-s1b,d0,a1 | |||||||||||||
| 12 Fiber Ribbons | 1728 | F-RRZLFK-12-B1-1728-E3 | 6 | 24 |
288 |
0.29 |
7.4 |
1.11 |
28.1 |
428 |
637 |
15,420 |
4,700 |
| 16 Fiber Ribbons | 1728 | F-RRZLFK-16-B1-1728-E3 | 6 | 18 | |||||||||
Global: M-RRIOLFK-12-B1-864-E3, M-RRIOLFK-12-B1-1152-E3, M-RRIOLFK-12-B1-1728-E3, RZIOLFK-12-B1-1152-E3, RZIOLFK-12-B1-1728-E3, M-RRZIOLFK-12-B1-1728-E3, M-RRZIOLFK-16-B1-1728-E3, M-RRLFK-12-B1-864-E3, M-RRLFK-12-B1-1152-E3, M-RRLFK-12-B1-1728-E3, RZLFK-12-B1-1152-E3, RZLFK-12-B1-1728-E3, M-RRZLFK-12-B1-1728-E3, M-RRZLFK-16-B1-1728-E3
Features and Benefits
Ultra Compact Design
- FlexRibbons are rolled up into compact 144 or 288-fiber sub-units for easier routing
- Significantly smaller diameter and lighter weight cables allow for easier installation and the use of smaller ducts
- A smaller, more flexible design where the ribbons, tubes, and cables can easily be bent in any direction
FlexRibbon Technology
- Extremely flexible ribbons can be rolled up for high packing densities or laid flat for ribbon splicing
- FlexRibbons are compatible with mass fusion heat strippers, cleavers, and splice machines
- Uses standard 250μm coated bend-insensitive fiber (ITU G657.A1)
Performance
- Uses full dry water blocking technology in the tubes and cable core for easy closure preparation and termination
- Tested in accordance with GR-20 and ICEA 696 and with relevant EIA/TIA-455 series FOTPs for fiber optic cables
Flame Retardant Construction
- Riser designs comply with UL 1666 and are OFNR and OFNG-FT4 rated
- OFNG design complies with UL 1685 type 2 test with smoke measurement and NFPA 130, and is OFNG-ST1 rated, with LSZH jacket material
- LSZH, Riser and CPR design complies with UL1666 and is OFNR and OFNG-FT4 rated, and complies with UL 1685 type 2 test with smoke measurement and NFPA 130 and is FT4 ST1 rated, and rated to CPR rating Cca-s1b,d0,a1, and is LSZH jacket material
Registered Supplier: ISO 9001, ISO 14001, TL 9000, and OHSAS 18001